MLSH01-0 Electromagnetic Lock
The MLSH01-0 is a surface mount electromagnetic lock featured with a built-in voltage spike
suppressor and a sensor. It can be applied for single-leaf or double-leaf doors.
Note: The product should only be powered by a UL listed power supply.
Packing List
1. MLSH01-0 electromagnetic lock x 1
2. Magnet faceplate x 1
3. Inner hexagon wrench x 1
4. M8 (35mm) screw + black rubber
spacer x 1
5. Hat nut x 1
6. Galvanized steel rivet x 2
7. Black rubber spacer x 2
8. Aluminum shim x 2
9. #10 (5/8”) screw x 2
10. #10 (1.25”) screw x 8
11. Washer x 2
12. Stainless steel bracket x 1
13. CU1201 screw + permanent magnet x 1
14. M4 (6mm) screw x 1
15. Inner hexagon nut x 1
16. Aluminum tube x 1
May 13, 2011
2
Installation
Before installing, add the thread lockers to all screws. Firmly tighten the screws to avoid
fastening loosen.
1. Install the electromagnetic lock to the doorframe.
Note: If the power switch is not wired between the DC source voltage and the magnet, it
will take longer to de-energize the magnet simulating residual magnetism.
Page view 0
1 2 3

Summary of Contents

Page 1 - Installation

May 13, 2011 1 MLSH01-0 Electromagnetic Lock The MLSH01-0 is a surface mount electromagnetic lock featured with a built-in voltage spike suppressor

Page 2

May 13, 2011 3 2. Mounts the armature plate to the door. Typical Installation of the electromagnetic lock: Note: To make the armat

Page 3 - Specifications

May 13, 2011 5 2. To connect the sensor to the GV-AS400, connect the Red wire of the sensor to the Input of the GV-AS400, and connect the Black wir