Geovision GV-AS110 User Manual Page 71

  • Download
  • Add to my manuals
  • Print
  • Page
    / 255
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 70
GV-AS110 / 1110 Controller
53
2
For example, to enable the Fixed Card + PIN
mode, press 5264#.
Open door
with card
number and
PIN code
_ _ _ _ _ _ _ _(_ _ _ _)#
Enter the 8-digit card
number and enter its 4-
digit PIN code.
To open the door without presenting a card, enter
the 8-digit card number on the back of the
individual card and its 4-digit PIN code.
Set ID
743_ _ _#
Enter an ID number
between 0 and 255.
Set an ID number for GV-AS110 / 1110 to a
number between 0 and 255.
For example, to set the ID number to be 3, press
743003#
Security Mode
276_ _ _ _#
4 digits PIN code of the
security card.
In the Security Mode, no cards can be granted
access and no one can program the unit. Only
the Security Card can disable the Security Mode.
To enable the Security Mode, press 276, enter
the PIN code of the Security Card and press #.
Present the Security Card.
To disable the Security Mode, simply press the
PIN code of the Security Card and present the
Security Card.
Two Person
Entrance
873_#
DisableÎ0
EnableÎ1
When Two Person Entrance mode is enabled,
both Two Person A Card and Two Person B Card
must be presented to unlock the entrance.
To enable Two Person Entrance, press 8731#
Two Person
Exit
879_#
DisableÎ0
EnableÎ1
When Two Person Exit mode is enabled, both
Two Person A Card and Two Person B Card
must be presented to unlock the exit.
To enable Two Person Exit, press 8791#
Select Input
Contact Type
426_ _ _#
NOÎ1
NCÎ0
Specify the input contact type of the door sensor
in the first blank digit, button in the second blank
digit and fire sensor in the third blank digit. The
default value is normally opened (NO). Note that
the third digit (fire sensor) is not functional for GV-
AS1110, so you can press either 1 or 0.
For example, to set the input contact type for door
sensor to be normally open (NO), button to be
normally closed (NC), and fire sensor to be
normally open (NO), press 426101#.
Load Default 362#
To restore GV-AS110 to factory default, press
362#. All configured settings will be cleared and
all cards will be deleted from GV-AS110 / 1110.
Note: The Parking Entry Type and Parking Exit Type only work when the sensor input of
Car Detection is activated.
Page view 70
1 2 ... 66 67 68 69 70 71 72 73 74 75 76 ... 254 255

Comments to this Manuals