GV-AS120 Controller
67
3
To define ID number, control type and authentication mode
Using the GV-AS120 Setting AP in the GV-ASManager folder, you can define the ID
number of multiple GV-AS120 connected through RS-485 interface, as well as set the
control type and authentication mode.
1. Go to C:\Access Control\ASManager\ and double-click GV-AS120 SetupAP
V100.exe. This dialog box appears.
Figure 3-7
2. Select the COM port that is connected to GV-AS120 and click Open COM. The red
square next to the COM port box should change to blue to indicate the COM port is
correct.
Note: To verify the COM port that is connected to GV-AS120, go to Windows Device
Manager. In the Ports (COM & LPT) field, you should see the entry for Prolific USB-to-
Serial Comm Port. The COM port shown in parenthesis indicates the COM number
currently in use.
3. Select an ID number for the GV-AS120.
4. Use the drop-down list to define the Control Type and Authentication Mode. Refer to
Door / Gate Function and Set Authentication Mode in 2.3.2 Programming the GV-AS110
for more details on each type of Control Type and Authentication Mode.
5. Click Setup GO. The settings are sent to GV-AS120.
Page view 84